This control from the “TOUCH” series is designed for the operation of vacuum chambers for wood drying. vacuTouch is equipped with a special multifunction sensor (LG35) to ensure optimal drying results. The system automatically detects the various sensors and functions for operating the vacuum chamber. The control can also be used for the operation of dual chamber systems (with or without drainage container, with or without humidification system). The possibility of vacuum variable drying and vacuum drying with heating plate system is also provided by vacuTouch.
As soon as the control detects a change in wood drying based on the measured values, it switches to vacuum variable operation. The setting of individual drying phases can be done in relation to the drying progress or based on a predefined duration. All sensors or actuators of the control can be automatically or manually controlled. It only takes a finger click on the correct icon in the control menu! In the same way, the individual parameters for drying can also be adjusted.
A major advantage of the vacuTouch system is that wireless sensors/actuators can be controlled. This facilitates handling with vacuum chambers with roll wagon loading, as no unnecessary lines are in the way or possibly could be damaged.
- Adjustment for plate heating or vacuum variable operation
- Setting of automatic/manual operation in vacuum variable drying
- Adjustment of the humidification system
- Timed setting for drainage container emptying
- Detection of operation for single or double chamber drying
- Possibility of using wireless sensors/actuators
- Time or drying progress-dependent setting possibility
- Drying cycle division into up to 30 phases
TECHNICAL DATA
SENSORS:
- 1 Hygrometer/EMC
- 1 Pressure gauge (absolute)
- 1 Temperature sensor (air)
- 1,(2) Temperature meter (wood)
- 1,(0) Temperature meter for plate heating system
- 4 Wood probes (moisture measurement)
OUTPUTS:
- Vacuum pump
- Air intake valve
- Ventilation (rotor direction, speed)
- Spraying
- Heating
- Humidification
- Dehumidification
- Drainage container
- Alarm / Heating pump
- 1 Auxiliary relay output
- 1 Auxiliary output 0-10V
INPUTS:
- External alarm
- Water volume regulation
- 2 Auxiliary inputs